DATACOM-XCVR-MIB DEFINITIONS ::= BEGIN

-- Partial MIB (RouterX custom) exposing DmOS transceiver DDM to LibreNMS.
-- Three real agent subtrees under enterprises.3709.3.6, all keyed by ifIndex:
--   .11.3  inventory + alarm/warning thresholds (per port)
--   .8.1   real-time temperature / voltage        (per port)
--   .8.2   real-time rx/tx power / bias current    (per port, per lane)

IMPORTS
    MODULE-IDENTITY, OBJECT-TYPE, enterprises, Integer32, Gauge32
        FROM SNMPv2-SMI
    DisplayString
        FROM SNMPv2-TC
    ifIndex
        FROM IF-MIB;

datacomXcvrMIB MODULE-IDENTITY
    LAST-UPDATED "202610050000Z"
    ORGANIZATION "RouterX"
    CONTACT-INFO  "Josi - RouterX"
    DESCRIPTION   "Partial DmOS transceiver DDM MIB for LibreNMS optical monitoring."
    REVISION      "202610050000Z"
    DESCRIPTION   "Values + thresholds mapped against DmOS CLI digital-diagnostics."
    ::= { enterprises 3709 }

-- ============ .3.6.11.3 : inventory + thresholds (index = ifIndex) ============
dmXcvrTable OBJECT-TYPE
    SYNTAX SEQUENCE OF DmXcvrEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION "Transceiver inventory and DDM thresholds."
    ::= { enterprises 3709 3 6 11 3 }

dmXcvrEntry OBJECT-TYPE
    SYNTAX DmXcvrEntry
    MAX-ACCESS not-accessible
    STATUS current
    DESCRIPTION "Entry."
    INDEX { ifIndex }
    ::= { dmXcvrTable 1 }

DmXcvrEntry ::= SEQUENCE {
    dmXcvrType        DisplayString,
    dmXcvrTempLoAlarm DisplayString, dmXcvrTempHiAlarm DisplayString,
    dmXcvrTempLoWarn  DisplayString, dmXcvrTempHiWarn  DisplayString,
    dmXcvrRxLoAlarm   DisplayString, dmXcvrRxHiAlarm   DisplayString,
    dmXcvrRxLoWarn    DisplayString, dmXcvrRxHiWarn    DisplayString,
    dmXcvrTxLoAlarm   DisplayString, dmXcvrTxHiAlarm   DisplayString,
    dmXcvrTxLoWarn    DisplayString, dmXcvrTxHiWarn    DisplayString,
    dmXcvrVoltLoAlarm DisplayString, dmXcvrVoltHiAlarm DisplayString,
    dmXcvrVoltLoWarn  DisplayString, dmXcvrVoltHiWarn  DisplayString,
    dmXcvrBiasLoAlarm DisplayString, dmXcvrBiasHiAlarm DisplayString,
    dmXcvrBiasLoWarn  DisplayString, dmXcvrBiasHiWarn  DisplayString
}

dmXcvrType        OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Compliance/type." ::= { dmXcvrEntry 4 }
dmXcvrTempLoAlarm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Temp low alarm (C)."  ::= { dmXcvrEntry 10 }
dmXcvrTempHiAlarm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Temp high alarm (C)." ::= { dmXcvrEntry 11 }
dmXcvrTempLoWarn  OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Temp low warn (C)."   ::= { dmXcvrEntry 12 }
dmXcvrTempHiWarn  OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Temp high warn (C)."  ::= { dmXcvrEntry 13 }
dmXcvrRxLoAlarm   OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Rx low alarm (dBm)."  ::= { dmXcvrEntry 14 }
dmXcvrRxHiAlarm   OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Rx high alarm (dBm)." ::= { dmXcvrEntry 15 }
dmXcvrRxLoWarn    OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Rx low warn (dBm)."   ::= { dmXcvrEntry 16 }
dmXcvrRxHiWarn    OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Rx high warn (dBm)."  ::= { dmXcvrEntry 17 }
dmXcvrTxLoAlarm   OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Tx low alarm (dBm)."  ::= { dmXcvrEntry 18 }
dmXcvrTxHiAlarm   OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Tx high alarm (dBm)." ::= { dmXcvrEntry 19 }
dmXcvrTxLoWarn    OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Tx low warn (dBm)."   ::= { dmXcvrEntry 20 }
dmXcvrTxHiWarn    OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Tx high warn (dBm)."  ::= { dmXcvrEntry 21 }
dmXcvrVoltLoAlarm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Vcc low alarm (V)."   ::= { dmXcvrEntry 22 }
dmXcvrVoltHiAlarm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Vcc high alarm (V)."  ::= { dmXcvrEntry 23 }
dmXcvrVoltLoWarn  OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Vcc low warn (V)."    ::= { dmXcvrEntry 24 }
dmXcvrVoltHiWarn  OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Vcc high warn (V)."   ::= { dmXcvrEntry 25 }
dmXcvrBiasLoAlarm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Bias low alarm (mA)." ::= { dmXcvrEntry 26 }
dmXcvrBiasHiAlarm OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Bias high alarm (mA)."::= { dmXcvrEntry 27 }
dmXcvrBiasLoWarn  OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Bias low warn (mA)."  ::= { dmXcvrEntry 28 }
dmXcvrBiasHiWarn  OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Bias high warn (mA)." ::= { dmXcvrEntry 29 }

-- ============ .3.6.8.1 : real-time temperature / voltage (index = ifIndex) ============
dmXcvrDiagTable OBJECT-TYPE
    SYNTAX SEQUENCE OF DmXcvrDiagEntry
    MAX-ACCESS not-accessible STATUS current
    DESCRIPTION "Real-time per-port temperature/voltage (scaled x100)."
    ::= { enterprises 3709 3 6 8 1 }
dmXcvrDiagE1 OBJECT IDENTIFIER ::= { dmXcvrDiagTable 1 }
dmXcvrDiagEntry OBJECT-TYPE
    SYNTAX DmXcvrDiagEntry MAX-ACCESS not-accessible STATUS current
    DESCRIPTION "Entry." INDEX { ifIndex } ::= { dmXcvrDiagE1 1 }
DmXcvrDiagEntry ::= SEQUENCE { dmXcvrDiagTemp Integer32, dmXcvrDiagVolt Integer32 }
dmXcvrDiagTemp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature, 0.01 C." ::= { dmXcvrDiagEntry 1 }
dmXcvrDiagVolt OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Voltage, 0.01 V."     ::= { dmXcvrDiagEntry 2 }

-- ============ .3.6.8.2 : real-time rx/tx power, bias (index = ifIndex, lane) ============
dmXcvrLaneTable OBJECT-TYPE
    SYNTAX SEQUENCE OF DmXcvrLaneEntry
    MAX-ACCESS not-accessible STATUS current
    DESCRIPTION "Real-time per-lane rx/tx power and bias (scaled x100)."
    ::= { enterprises 3709 3 6 8 2 }
dmXcvrLaneE1 OBJECT IDENTIFIER ::= { dmXcvrLaneTable 1 }
dmXcvrLaneEntry OBJECT-TYPE
    SYNTAX DmXcvrLaneEntry MAX-ACCESS not-accessible STATUS current
    DESCRIPTION "Entry." INDEX { ifIndex, dmXcvrLaneNum } ::= { dmXcvrLaneE1 1 }
DmXcvrLaneEntry ::= SEQUENCE {
    dmXcvrLaneNum  Integer32,
    dmXcvrRxDbm    Integer32,
    dmXcvrTxDbm    Integer32,
    dmXcvrBias     Integer32
}
dmXcvrLaneNum OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS not-accessible STATUS current DESCRIPTION "Lane number." ::= { dmXcvrLaneEntry 1 }
dmXcvrRxDbm   OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Rx power, 0.01 dBm." ::= { dmXcvrLaneEntry 2 }
dmXcvrTxDbm   OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Tx power, 0.01 dBm." ::= { dmXcvrLaneEntry 3 }
dmXcvrBias    OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Tx bias, 0.01 mA."   ::= { dmXcvrLaneEntry 4 }

-- ============ .3.6.6.1.3 : equipment temperature sensors (scaled x10) ============
dmEnvTempTable OBJECT-TYPE
    SYNTAX SEQUENCE OF DmEnvTempEntry
    MAX-ACCESS not-accessible STATUS current
    DESCRIPTION "Board/CPU/fabric/PSU temperature sensors."
    ::= { enterprises 3709 3 6 6 1 3 }
dmEnvTempEntry OBJECT-TYPE
    SYNTAX DmEnvTempEntry MAX-ACCESS not-accessible STATUS current
    DESCRIPTION "Entry." INDEX { dmEnvTempUnit } ::= { dmEnvTempTable 1 }
DmEnvTempEntry ::= SEQUENCE {
    dmEnvTempUnit Integer32, dmEnvTempName DisplayString,
    dmEnvTempHiAlarm Integer32, dmEnvTempValue Integer32
}
dmEnvTempUnit    OBJECT-TYPE SYNTAX Integer32     MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unit." ::= { dmEnvTempEntry 1 }
dmEnvTempName    OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Sensor name."        ::= { dmEnvTempEntry 2 }
dmEnvTempHiAlarm OBJECT-TYPE SYNTAX Integer32     MAX-ACCESS read-only STATUS current DESCRIPTION "High alarm, 0.1 C."  ::= { dmEnvTempEntry 3 }
dmEnvTempValue   OBJECT-TYPE SYNTAX Integer32     MAX-ACCESS read-only STATUS current DESCRIPTION "Temperature, 0.1 C." ::= { dmEnvTempEntry 6 }

-- ============ .3.6.6.1.4 : fans (RPM) ============
dmEnvFanTable OBJECT-TYPE
    SYNTAX SEQUENCE OF DmEnvFanEntry
    MAX-ACCESS not-accessible STATUS current
    DESCRIPTION "Fan tray speeds."
    ::= { enterprises 3709 3 6 6 1 4 }
dmEnvFanEntry OBJECT-TYPE
    SYNTAX DmEnvFanEntry MAX-ACCESS not-accessible STATUS current
    DESCRIPTION "Entry." INDEX { dmEnvFanUnit } ::= { dmEnvFanTable 1 }
DmEnvFanEntry ::= SEQUENCE {
    dmEnvFanUnit Integer32, dmEnvFanName DisplayString, dmEnvFanRpm Gauge32
}
dmEnvFanUnit OBJECT-TYPE SYNTAX Integer32     MAX-ACCESS not-accessible STATUS current DESCRIPTION "Unit." ::= { dmEnvFanEntry 1 }
dmEnvFanName OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Fan name." ::= { dmEnvFanEntry 2 }
dmEnvFanRpm  OBJECT-TYPE SYNTAX Gauge32       MAX-ACCESS read-only STATUS current DESCRIPTION "Fan speed, RPM." ::= { dmEnvFanEntry 4 }

-- ============ .3.6.11.2 : chassis / module / PSU inventory + status ============
dmInvTable OBJECT-TYPE
    SYNTAX SEQUENCE OF DmInvEntry
    MAX-ACCESS not-accessible STATUS current
    DESCRIPTION "Chassis, module and power-supply inventory."
    ::= { enterprises 3709 3 6 11 2 }
dmInvEntry OBJECT-TYPE
    SYNTAX DmInvEntry MAX-ACCESS not-accessible STATUS current
    DESCRIPTION "Entry." INDEX { dmInvIdx } ::= { dmInvTable 1 }
DmInvEntry ::= SEQUENCE { dmInvIdx Integer32, dmInvName DisplayString, dmUnitStatus Integer32 }
dmInvIdx     OBJECT-TYPE SYNTAX Integer32     MAX-ACCESS not-accessible STATUS current DESCRIPTION "Index." ::= { dmInvEntry 1 }
dmInvName    OBJECT-TYPE SYNTAX DisplayString MAX-ACCESS read-only STATUS current DESCRIPTION "Unit name (e.g. 1/PSU2)." ::= { dmInvEntry 2 }
dmUnitStatus OBJECT-TYPE SYNTAX Integer32     MAX-ACCESS read-only STATUS current DESCRIPTION "Operational status (1=OK)." ::= { dmInvEntry 18 }

END