ECOSWITCH-HARDWARE-INFO-MIB DEFINITIONS ::= BEGIN

--
-- Hardware information of SDN SWITCH platform
--

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    enterprises,
    Counter64,
    Integer32,
    Unsigned32
        FROM SNMPv2-SMI
    OBJECT-GROUP
        FROM SNMPv2-CONF;


rdp MODULE-IDENTITY
    LAST-UPDATED "202409100000Z"
    ORGANIZATION "RDP.RU"
    CONTACT-INFO "web:      http://rdp.ru"
    DESCRIPTION  "Includes information about hardware"
    REVISION     "202409100000Z"
    DESCRIPTION
        "Initial version"
    ::= { enterprises 45555 }

ecoswitch     OBJECT IDENTIFIER ::= { rdp 3 }
hardwareInfo  OBJECT IDENTIFIER ::= { ecoswitch 3 }

productObjects OBJECT-GROUP
    OBJECTS {
                serialNumber,
                productName,
                biosVersion,
                cpuCoreNumber,
                cpuCoreLoad,
                total,
                free,
                utilization,
                storageDevice,
                storageType,
                storageTotal,
                storageFree,
                storageUtilization,
                psuNumber,
                psuType,
                psuStatus,
                psuInputVoltage,
                psuInputCurrent,
                psuOutputVoltage,
                psuOutputCurrent,
                fanNumber,
                fanState,
                fanSpeedFront,
                fanSpeedRear,
                sensorsAdapterName,
                sensorsAdapterParameterName,
                sensorsAdapterParameterValue
            }
    STATUS  current
    DESCRIPTION
        "The group of objects that constitute the information
        about hardware"
::= { hardwareInfo 8 }

--
-- platform info
--

platformInfo  OBJECT IDENTIFIER ::= { hardwareInfo 1 }

serialNumber OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Product Serial Number"
    ::= { platformInfo 1 }

productName OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Product name"
    ::= { platformInfo 2 }

biosVersion OBJECT-TYPE
    SYNTAX      OCTET STRING
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "BIOS version"
    ::= { platformInfo 3 }

--
-- CPU Info
--

cpuInfoTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF CpuInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about CPUs"
    ::= { hardwareInfo 2 }

cpuInfoEntry OBJECT-TYPE
    SYNTAX      CpuInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    ""
    INDEX { cpuCoreNumber }
    ::= { cpuInfoTable 1 }

CpuInfoEntry ::=
    SEQUENCE {
        cpuCoreNumber Unsigned32,
        cpuCoreLoad   Unsigned32
    }

    cpuCoreNumber OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Core number"
        ::= { cpuInfoEntry 1 }

    cpuCoreLoad OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "CPU utilization percentage"
        ::= { cpuInfoEntry 2 }

--
-- Memory Info
--

memoryInfo  OBJECT IDENTIFIER ::= { hardwareInfo 3 }

total OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Total capacity"
    ::= { memoryInfo 1 }

free OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Free memory"
    ::= { memoryInfo 2 }

utilization OBJECT-TYPE
    SYNTAX      Unsigned32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Utilization in percents"
    ::= { memoryInfo 3 }

--
-- Storage Info
--

storageInfoTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF StorageInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about storage devices"
    ::= { hardwareInfo 4 }

storageInfoEntry OBJECT-TYPE
    SYNTAX      StorageInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    ""
    INDEX { storageDevice }
    ::= { storageInfoTable 1 }

StorageInfoEntry ::=
    SEQUENCE {
        storageDevice   Unsigned32,
        storageType OCTET STRING,
        storageTotal    Counter64,
        storageFree Counter64,
        storageUtilization  Unsigned32
    }

    storageDevice OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Storage device number"
        ::= { storageInfoEntry 1 }

    storageType OBJECT-TYPE
        SYNTAX      OCTET STRING
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Storage device type"
        ::= { storageInfoEntry 2 }

    storageTotal OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Total capacity"
        ::= { storageInfoEntry 3 }

    storageFree OBJECT-TYPE
        SYNTAX      Counter64
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Free memory"
        ::= { storageInfoEntry 4 }

    storageUtilization OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Utilization in percents"
        ::= { storageInfoEntry 5 }

--
-- PSU Info
--

psuInfoTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF PsuInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about power consumption"
    ::= { hardwareInfo 5 }

psuInfoEntry OBJECT-TYPE
    SYNTAX      PsuInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    ""
    INDEX { psuNumber }
    ::= { psuInfoTable 1 }

PsuInfoEntry ::=
    SEQUENCE {
        psuNumber Unsigned32,
        psuType INTEGER,
        psuStatus INTEGER,
        psuInputVoltage Unsigned32,
        psuInputCurrent Unsigned32,
        psuOutputVoltage Unsigned32,
        psuOutputCurrent Unsigned32
    }

    psuNumber OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "PSU number"
        ::= { psuInfoEntry 1 }

    psuType OBJECT-TYPE
        SYNTAX  INTEGER {
                  unknown(0),
                  AC(1),
                  DC(2)
                }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "PSU type"
        ::= { psuInfoEntry 2 }

    psuStatus OBJECT-TYPE
        SYNTAX  INTEGER {
                  unknown(0),
                  PowerOn(1),
                  PowerOff(2)
                }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "PSU status"
        ::= { psuInfoEntry 3 }

    psuInputVoltage OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Input voltage, mV"
        ::= { psuInfoEntry 4 }

    psuInputCurrent OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Input current, mA"
        ::= { psuInfoEntry 5 }

    psuOutputVoltage OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Output voltage, mV"
        ::= { psuInfoEntry 6 }

    psuOutputCurrent OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Output current, mA"
        ::= { psuInfoEntry 7 }

--
-- fan Info
--

fanInfoTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF FanInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Information about fans"
    ::= { hardwareInfo 6 }

fanInfoEntry OBJECT-TYPE
    SYNTAX      FanInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    ""
    INDEX { fanNumber }
    ::= { fanInfoTable 1 }

FanInfoEntry ::=
    SEQUENCE {
        fanNumber Unsigned32,
        fanState INTEGER,
        fanSpeedFront Unsigned32,
        fanSpeedRear Unsigned32
    }

    fanNumber OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Fan number"
        ::= { fanInfoEntry 1 }

    fanState OBJECT-TYPE
        SYNTAX  INTEGER {
                  unknown(0),
                  active(1),
                  inactive(2)
                }
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Fan state"
        ::= { fanInfoEntry 2 }

    fanSpeedFront OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Fan speed in revolutions per minute"
        ::= { fanInfoEntry 3 }

    fanSpeedRear OBJECT-TYPE
        SYNTAX      Unsigned32
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Fan speed in revolutions per minute"
        ::= { fanInfoEntry 4 }

--
-- Sensors Info
--

sensorsInfoTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF SensorsInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    ""
    ::= { hardwareInfo 7 }

sensorsInfoEntry OBJECT-TYPE
    SYNTAX      SensorsInfoEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
    ""
    INDEX { sensorsAdapterName, sensorsAdapterParameterName }
    ::= { sensorsInfoTable 1 }

SensorsInfoEntry ::=
    SEQUENCE {
        sensorsAdapterName OCTET STRING,
        sensorsAdapterParameterName OCTET STRING,
        sensorsAdapterParameterValue OCTET STRING
    }

    sensorsAdapterName OBJECT-TYPE
        SYNTAX      OCTET STRING
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Name of the sensor"
        ::= { sensorsInfoEntry 1 }

    sensorsAdapterParameterName OBJECT-TYPE
        SYNTAX      OCTET STRING
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
            "Name of sensor's parameter"
        ::= { sensorsInfoEntry 2 }

    sensorsAdapterParameterValue OBJECT-TYPE
        SYNTAX      OCTET STRING
        MAX-ACCESS  read-only
        STATUS      current
        DESCRIPTION
        ""
        ::= { sensorsInfoEntry 3 }

END